Standard equipment specifications

Capacity 20-10,000Nm3/h
Operating pressure 0.8-4Mpa·G
Operating temperature 240-290℃

Standard product gas composition

Pressure 0.8-4Mpa·G
Temperature up to 45℃
Dew point below -70℃
Purity H2 99.9~99.999vol%
CO 1.0ppm or less
CO2 1.0ppm or less

Standard unit of output --expected value of about 1Nm3--

Methanol 0.58kg
Purified water 0.32kg
Supplement fuel (A Fuel Oil) 0.04kg
Cooling water (△T=10℃) 0.02ton
Electric power 0.04kWh

Ground-floor area

Production capacity (Nm3/h) Length(m) Width(m) Height(m)
100 5 5 6
300 6 6 7
500 7 7 8
1000 9 9 8
2000 12 12 9

*Above figures are approximate. It is possible to adapt the layout to the site.

Patents

Published unexamined patent application No. 59-131501
Published unexamined patent application No. 59-131502
Published unexamined patent application No. 59-152205
Published unexamined patent application No. 59-189937
Published unexamined patent application No. 62-049947
Published unexamined patent application No. 62-246803
Published unexamined patent application No. 62-260702